These devices are equipped for the security of its users with multiple motion sensors that will shut-off the device in the presence of any motion. The devices all have preset off control that allows the user to set the timing and leave the room without any exposure.
Space-500 model can sanitize any room of 20 feet by 20 feet in minutes.
Space-1000 model has 65" long vertical lamps to even expose bottom sides of tables, chairs. The device is equipped with patent-pending floor UVC sanitizer that even covers the floor beneath the pedestal.
Construction: Solid stainless steel
Dimensions: 18" x 24" x 79.5" high
Operation: Timer with delay, so operator can safely leave the room
Frequency of use: As often as desired
Light intensity: 155 microWatt/sqcm @ 8 feet distance
Influenza virus kill rate: 43 seconds @ 8 feet distance, 99.9% effective
Enclosure: Quartz secondary protection of lamps and lamp protection cage
Light source: Hard quartz, non-ozone type
Number of lamps: 4 lamps SHO
Power input: 120 VAC 60 Hz, 230 VAC 50 Hz
Amperage: 4.5 Amps @ 120 VAC, 2.5 Amps @ 230 VAC
Power inlet: EMC filtration (hospital grade) at the power inlet
Power cord: Standard, 15 Amp @120 VAC IEC grounded with fuses
Lamp Life: 16,000 hours
Safety devices: Entry fuses, on/off switch, delay timer
Special features: Floor irradiation under equipment base via UVC lamp
Construction: Solid stainless steel and aluminum
Dimensions: 21" x 19" x 79.5" high
Operation: Timer with delay, so operator can safely leave the room
Frequency of use: As often as desired
Light intensity: 185 microWatt/sqcm @ 8 feet distance
Reflector: Super polished UV reflectors
Light source: Hard quartz, non-ozone type
Number of lamps: 5 lamps, Including under unit floor UVC (patent pending)
Power input: 120 VAC 60 Hz, 220 VAC 50 Hz
Amperage: 6.1 Amps @ 120 VAC (model SHO), 3.5 Amps @ 230 VAC 50 Hz
Power inlet: EMC filtration (hospital grade) at the power inlet
Power cord: Standard, 15 Amp @120 VAC IEC grounded with fuses
Lamp Life: 16,000 hours
Safety devices: Entry fuses, on/off switch, delay timer, 360° motion sensor shut off
Do not look directly at the lamps without wearing eye protection. Do not expose skin to the light; it may cause severe burns in a few seconds.
EPA Registered, Conforms to CSA/NRTL/ANSI, UL1431 standards manufactured with ISO 13485-2016 quality controls.
Note: This is not a medical device.